Skip to content
Search Canton

Canton, Massachusetts · Saved source text

3-7-12 Mins

Conservation · Source meeting date: 2012-03-07 · Record 47396

Open original municipal record ↗Open interactive reader

Saved text from 1 of 7 source pages. Transcription and OCR may contain errors; verify figures and wording against the original.

Source page 1

Canton Conservation Commission 
Pequitside Farm —Tavern Room 
79 Pleasant Street 
Canton, Ma. 02021 
March 7, 2012 
Minutes 
Attendance: Deb Sundin — Chairman, Tom Liddy - Vice- Chairman, James Fitzpatrick — Clerk 
Robert MacDonald, Bruce Rohr 
Absent: Robert Doe 
Conservation Agent: Robert Murphy 
Recording Secretary: Heather Cahill 
Hearing called to order at 7:00 P.M. by Chairman Deb Sundin 
Minutes of January 18, 2012, February 15, 2012 
To be voted at March 21, 2012 hearing. 
PUBLIC HEARING 
7:10 P.M. 
Dana Scievour 8 South Street 
Presented by George Collins, Collins Engineering. 
Plan Title: Plan to Accompany Building Permit and Conservation Applications. 
124 — 1084 
Plan Dated: 2/14/12 
Scale: As Shown Stamped by: George R. Collins, P.E. 
• Construction of 4 bedroom, single-family home on Canton/Stoughton line. 
• Offsite wetland to west of proposed project is associated with an unknown intermittent 
stream. 
• Wetlands delineated by Walter Hewitson, PhD., Botanist. 
• Wetland flags were located using acceptable survey practices by Collins Engineering 
Group, Inc. 
• Stream has been determined to be intermittent based on sub catchment area analysis and 
verbal testimony from owner of South Street. 
• Silt fence and hay bales to be installed. 
• Crushed stone tracking pad to be used at entrance of construction site. 
• Septic tank 440 GPD x 20 = 880 gallons, will use a (2) compartment 1500-gallon septic 
tank with 1,000 gallon primary compartment and 500 gallon secondary compartment. 
• 16'.4" x 25' leaching bed with (50 rows of (5) Ads Arc 36 Leaching Chambers. 
• Ads Arc Leaching Chamber area = 4.8 square feet/linear feet. 
1 
by Heather Cahill