Canton, Massachusetts · Saved source text
7-16-08 Mins
Saved text from 1 of 8 source pages. Transcription and OCR may contain errors; verify figures and wording against the original.
Source page 1
Canton Conservation Commission Pequitside Farm — Tavern Room 79 Pleasant Street Canton, Ma. 02021 July 16, 2008 MEETING MINUTES PUBLIC HEARING Attendance: Chairman — Robert Doe, Vice-Chairman Deb Sundin, Clerk - James Fitzpatrick, Dave McLelland, Kate Merrigan, Tom Liddy Absent: Robert MacDonald Conservation Agent: Robert Murphy Recording Secretary: Heather Cahill Chairman Robert Doe calls hearing to order at 7:03 P.M. Minutes: June 18, 2008 Motion Made by Kate Merrigan to accept as amended the minutes of June 18, 2008. Seconded by Deb Sundin Vote: Yes - 6 No —0 7:10 P.M. GENERAL DISCUSSION John Marini Rockland Street (AMOOC) DEP 124-970 Represented by John Rhoads of Norwood Engineering Amended Order of Conditions will need to be readvertised, due to significant change in drainage. Mr. Rhoads explained to ConCom that after lengthy discussion with Town engineer and Conservation Agent Robert Murphy that there is a significant change in drainage of Flood storage compared to original Notice of Intent that was filed. Amended Order of Conditions were to include changes to site grading, sidewalk locations and materials, emergency fire access road and modified compensatory flood storage. During field changes which were minor but didn't meet the compliance standards established in Town of Canton's Wetland Bylaw. Changes include: 1. Location change and material change for walkways associated with the duplex unit at 25 Rockland Street. Material change was brick pavers to cement concrete. 2. Material change for walkway along easterly face of the 16 — unit building from brick pavers to cement concrete. 3. Sidewalk and curbing added at the driveway entrance on the property of 515 Washington St. Realty Trust. 4. Fire lane was modified. Original plan proposed a 14 foot wide fire lane to run from the end of pavement at the building's north face along the easterly landscaped area and out to a paved private way on land of Pine Realty Trust. Now proposed to provide three access points to the easterly face of the building. First access will be an extension from the current access drive adjacent to the electrical transformer. 5. Two additional gravel surface fire access points that are partially constructed from the private way on Pine Realty Trust property. Access points will require fine grading and compacting, these access points have been approved by Canton Fire Department. 6. Compensatory flood storage requirements are proposed to construct an open storage area at on the west bank of Massapoag Brook immediately up gradient of twin culverts. Area will provide compensatory storage from elevation 96 to 99. 1 7/16/08 hc